Product Features

LCD Startup and Main Interface

LED Indicators
![]() |
![]() |
PV array indicator | Indicating the controller's current charging mode. |
| BAT indicator | Indicating the battery's current state. | ||
| LOAD indicator | Indicating the loads' On/ Off and state. | ||
| ERROR indicator | Indicating whether the controller is functioning normally. |
PV array indicator:
| No. | Graph | Indicator state | Charging state |
| ① | ![]() |
Steady on | MPPT charging |
| ② | ![]() |
Slow flashing
(a cycle of 2s with on and off each lasting for 1s) |
Boost charging |
| ③ | ![]() |
Single flashing
(a cycle of 2s with on and off lasting respectively for 0.1s and 1.9s) |
Floating charging |
| ④ | ![]() |
Quick flashing
(a cycle of 0.2s with on and off each lasting for 0.1s) |
Equalizing charging |
|
⑤ |
![]() |
Double flashing
(a cycle of 2s with on for 0.1s, off for 0.1s, on again for 0.1s, and off again for 1.7s) |
Current-limited charging |
| ⑥ | Off | No charging |
BAT indicator:
| Indicator state | Battery state |
| Steady on | Normal battery voltage |
| Slow flashing (a cycle of 2s with on and off each lasting for 1s) | Battery over-discharged |
| Quick flashing (a cycle of 0.2s with on and off each lasting for 0.1s) | Battery over-voltage |
LOAD indicator:
| Indicator state | Battery state |
| Off | Load turned off |
| Quick flashing (a cycle of 0.2s with on and off each lasting for 0.1s) | Load overloaded/ short-circuited |
| Steady on | Load functioning normally |
ERROR indicator:
| Indicator state | Battery state |
| Off | System operating normally |
| Steady on | System malfunctioning |
Key Operations
| ▲Up | Page up; increase the parameter value in setting |
| ▼Down | Page down; decrease the parameter value in setting |
| ►Return | Return to previous menu (exit without saving) |
| ◄Set | Enter into sub-menu; set/ save
Turn on/ off loads (in manual mode) |



1.Electric Parameters
| Parameter | Value | ||
| Model | MH-R2420 | MH-R2430 | MH-R2440 |
| System voltage | 12V/24VAuto | ||
| No-load loss | 0.7 W to 1.2W | ||
| Battery voltage | 9V to 35V | ||
| Max. solar input voltage | 100V(25℃)90V(-25℃) | ||
| Max. power point voltage range | Battery Voltage+2V to 75V | ||
| Rated charging current | 20A | 30A | 40A |
| Rated load current | 20A | ||
| Max. capacitive load capacity | 10000uF | ||
| Max. photovoltaic system input power | 260W/12V
520W/24V |
400W/12V
800W/24V |
520W/12V
1040W/24V |
| Conversion efficiency | ≤98% | ||
| MPPT tracking efficiency | >99% | ||
| Temperature compensation factor | -3mv/℃/2V(default) | ||
| Operating temperature | -35℃ to +45℃ | ||
| Protection degree | IP32 | ||
| Weight | 1.4Kg | 2Kg | 2Kg |
| Communication method | RS232 | ||
| Altitude | ≤ 3000m | ||
| Product dimensions | 210*151*59.5mm | 238*173*72.5mm | 238*173*72.5mm |
2.Battery Type Default Parameters (parameters set in monitor software)
| Parameters cross-reference table for different types of batteries | ||||
| Voltage to set Battery type | Sealed lead-acid battery | Gel lead-acid battery | Open lead-acid battery | User (self-customized) |
| Over-voltage cut-off voltage | 16.0V | 16.0V | 16.0V | 9~17V |
| Equalizing voltage | 14.6V | —— | 14.8V | 9~17V |
| Boost voltage | 14.4V | 14.2V | 14.6V | 9~17V |
| Floating charging voltage | 13.8V | 13.8V | 13.8V | 9~17V |
| Boost return voltage | 13.2V | 13.2V | 13.2V | 9~17V |
| Low-voltage cut-off return voltage | 12.6V | 12.6V | 12.6V | 9~17V |
| Under-voltage warning return voltage | 12.2V | 12.2V | 12.2V | 9~17V |
| Under-voltage warning voltage | 12.0V | 12.0V | 12.0V | 9~17V |
| Low-voltage cut-off voltage | 11.1V | 11.1V | 11.1V | 9~17V |
| Discharging limit voltage | 10.6V | 10.6V | 10.6V | 9~17V |
| Over-discharge time delay | 5s | 5s | 5s | 1~30s |
| Equalizing charging duration | 120minutes | —— | 120minutes | 0~600minutes |
| Equalizing charging interval | 30days | 0days | 30days | 0~250D
(0 means the equalizing charging function is disabled) |
| Boost charging duration | 120minutes | 120minutes | 120minutes | 10~600minutes |
When selecting User, the battery type is to be self-customized, and in this case, the default system voltage parameters are consistent with those of the sealed lead-acid battery. When modifying battery charging and discharging parameters, the following rule must be followed: