Features:
Model |
LPV-20-5 |
LPV-20-12 |
LPV-20-15 |
LPV-20-24 |
|
Output |
DC voltage |
5V |
12V |
15V |
24V |
Rated current |
3A |
1.67A |
1.33A |
0.84A |
|
Current range |
0~3A |
0~1.67A |
0~1.33A |
0~0.84A |
|
Rated power |
15W |
20W |
20W |
20.2W |
|
Ripple&noise (max.) |
80mVp-p |
120mVp-p |
120mVp-p |
150MVp-p |
|
Voltage tolerance |
±5.0% |
||||
Line regulation |
±1.0% |
||||
Load regulation |
±2.0% |
||||
Setup,rise time |
500ms, 20ms / 230VAC 500ms, 20ms / 115VAC at full load |
||||
Hold up time |
50ms/230VAC 16ms/115VAC at full load |
||||
Input |
Voltage range |
90 ~ 264VAC 127 ~ 370VDC |
|||
Frequency range |
47 ~ 63Hz |
||||
Efficiency |
77% |
81% |
83% |
83% |
|
AC current |
0.55A/115VAC 0.35A/230VAC |
||||
Inrush current |
Cold start 70A(twidth=215μs measured at 50% Ipeak) at 230VAC |
||||
Leakage current |
<0.25mA/240VAC |
||||
Protection |
Overload |
110 ~ 150% rated output power |
|||
Protection type:hiccup mode,auto-recovery after fault condition is removed |
|||||
Over voltage |
5.75~ 6.75V |
13.8~ 16V |
17.5~ 21V |
28~32V |
|
Protection type : Shut off o/p voltage, clamping by zener diode |
|||||
Environment |
WORKING TEMP. |
-30 ~ +70¢J (Refer to "Derating Curve") |
|||
Working humidity |
20%~90%RH non-condensing |
||||
Storage temp,humidity |
-40℃~+80℃,10%~95%RH non-condensing |
||||
Temp. coefficient |
±0.03%/℃(0 ~ 50℃) |
||||
Vibration |
10~500HZ,2G 10min/1cycle,period for 60min, X.Y.Z each axes |
||||
Safety&EMC |
Safety standard |
UL879, UL1310, CSA C22.2 No. 207-M89, CAN/CSA C22.2 No. 223-M91, IP67 approved ; design refer to TUV EN60950-1 |
|||
Withstand voltage |
I/P-O/P:3KVAC |
||||
Isolation resistance |
I/P-O/P:>100M Ohms / 500VDC / 25℃/ 70% RH |
||||
EMC emission |
Compliance to EN55022 Class B,EN61000-3-2 Class A, EN61000-3-3 |
||||
EMC immunity |
Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, light industry level, criteria A |
||||
Others |
MTBF |
786.5Khrs min. MIL-HDBK-217F (25¢J) |
|||
Dimension |
118*35*26mm (L*W*H) |
||||
Packing |
0.22Kg; 60pcs/14.2Kg/0.62CUFT |
NOTE:
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Derating may be needed under low input voltage. Please check the static characteristics for more details.
5. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the
complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.
6. Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to increase of the set up time.
7. Suitable for indoor use or outdoor use without direct sunlight exposure. Please avoid immerse in the water over 30 minute.
8. The unit might not be suitable for lighting applications in EU countries. Please check with your local authorities for the possible use of the unit.
The solar charge controller in a solar system is a key device to ensure that the battery can be charged safely and efficiently. When we talk about 300W solar panels,...
Solar panels are the preferred device for many people to use clean energy. They can directly convert sunlight into electricity to provide power for various devices. ...
In daily life or outdoor activities, the use of inverters is very common, especially inverters with a power range like 1000W, which can provide stable power support ...
When using a solar system, it is important to understand the charging speed of the solar panel and solar charge controller, especially when you need to charge a 100A...
GET A QUOTE