HS-350W Series Compact Single Switching Power Supply

HS-350W Series Compact Single Switching Power Supply
HS-350W Series Compact Single Switching Power Supply

Features:

  • AC input voltage range selected by switch
  • Small volume,low weight,high efficiency
  • Protections:short circuit/over load/over voltage/over temp
  • Built-in cooling DC fan
  • Cooling fan ON-OFF auto control
  • LED indicator for power on
  • 100% full load burn-in test
  • 2 Years warranty

Model

HS-350-5

HS-350-12

HS-350-15

HS-350-24

HS-350-27

HS-350-48

output

DC voltage

5V

12V

15V

24V

27V

48V

Voltage tolerance

±2%

±1%

±1%

±1%

±1%

±1%

Rated current

50A

29A

23A

14.6A

13

7.3

Current range

0~50A

0~29A

0~23A

0~14.6A

0~13A

0~5.2A

Rated power

250W

348W

345W

350.4W

351W

350.4W

Ripple&noise

150mvp-p

150mvp-p

150mvp-p

180mvp-p

180mvp-p

200mvp-p

DCvoltage ADJ.range

-9%~+10%

±10%

±10%

±10%

±10%

±10%

input

Voltage range

90~132VAC/180~264VAC(selected by switch),255~373VDC

frequency

47~63HZ

AC current

6.5A/115VAC,4.0A/230VAC

efficiency

80%

82%

82%

84%

84%

85%

Inrush current

Cold start current25A/115VAC,50A/230VAC

Leakage current

< 3.5mA/240VAC

protection

overload

Rated output power110%~135% start over load protection

protection type:hiccup mode,auto-recovery after fault condition is removed

Over voltage

6.8~8.2V

15.6~17.8V

18.6~20.8V

30.6~33.2V

33.2~35.6V

54.8~56.6V

Protection type:hiccup mode,auto-recovery after fault condition is removed

Over temperature

TSW1detect on heatsink of power transistor≥85℃±5℃, start over temperature protection

protection type:hiccup mode,auto-recovery after temperature become normal

environment

Working temp,humidity

-10℃~+60℃,20%~90%RH

Storage temp,humidity

-20℃~+85℃,10%~95%RH non-condensing

Withstand vibration

10~500HZ,2G10min/1cycle,period for 60 minutes,each axes

safety

Withstand voltage

I/P-O/P:1.5KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC

Isolation resistance

I/P-O/P,I/P-FG,O/P-FG:100Mohms/500VDC

Fit standard

Safety standard

Compliance to UL1012

EMC standard

Compliance to EN55022,CLASSA

others

Dimension

199*99*48mm(L*W*H)

Weight/packing

0.8kg/24pcs/20kg/0.034 m³/1.2CUFT

note

1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and25℃of ambient temperature.

2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.

3. Tolerance : includes set up tolerance, line regulation and load regulation.

> Technical Information

> What size breaker between solar panels and solar charge controller?

In a solar power generation system, the installation of a circuit breaker is a key step to ensure the safety of the system. The circuit breaker can not only prevent ...

> How big of solar charge controllers do I need?

The solar charge controller is one of the core components of the solar energy system. Its main function is to regulate the process of solar panels charging the batte...

> Can a 12-volt 75Ah battery run a 1000 watts inverter?

In solar systems, car power supplies, and emergency power systems, the combination of 12V batteries and 1000W inverters is common. However, can a 12V battery with a ...

> Can you leave a solar battery charger and solar charge controller on all the time?

In a solar system, solar battery chargers and charge controllers are key components. Many users are curious whether these devices can be left connected all the time?...

GET A QUOTE

Get in Touch

×