Features:
AC input voltage range selected by switch
Small volume,low weight,high efficiency
Protections:short circuit/over load/over voltage
cooling by free air convection
LED indicator for power on
100% full load burn-in test
2 Years warranty
Model |
HS-100-5 |
HS-100-12 |
HS-100-15 |
HS-100-24 |
HS-100-36 |
HS-100-48 |
|
output |
DC voltage |
5V |
12V |
15V |
24V |
36V |
48V |
Voltage tolerance |
±2% |
±1% |
±1% |
±1% |
±1% |
±1% |
|
Rated current |
20A |
8.3A |
6.7A |
4.2A |
2.8A |
2A |
|
Current range |
0~20A |
0~8.3A |
0~6.7A |
0~4.2A |
0~2.8A |
0~2A |
|
Rated power |
100W |
99.6W |
100.5W |
100.8W |
100.8W |
96W |
|
Ripple&noise |
80mvp-p |
120mvp-p |
120mvp-p |
150mvp-p |
150mvp-p |
180mvp-p |
|
DCvoltage ADJ.range |
-9%~+10% |
±10% |
±10% |
±10% |
±10% |
±10% |
|
input |
Voltage range |
90~132VAC/180~264VAC(selected by switch),254~373VDC |
|||||
frequency |
47~63HZ |
||||||
AC current |
2.4A/115VAC,1.2A/230VAC |
||||||
efficiency |
79% |
83% |
83% |
85% |
85% |
86% |
|
Inrush current |
Cold start current18A/115VAC,36A/230VAC |
||||||
Leakage current |
< 3.5mA/240VAC |
||||||
protection |
overload |
Rated output power115%~150% start over load protection |
|||||
protection type:hiccup mode,auto-recovery after fault condition is removed |
|||||||
Over voltage |
6.8~8.2V |
15.6~17.8V |
18.6~20.8V |
30.6~33.2V |
42.6~44.2V |
54.8~56.6V |
|
protection type:hiccup mode,auto-recovery after fault condition is removed |
|||||||
----- |
----- |
||||||
----- |
|||||||
environment |
Working temp,humidity |
-10℃~+60℃,20%~90%RH |
|||||
Storage temp,humidity |
-20℃~+85℃,10%~95%RH non-condensing |
||||||
Withstand vibration |
10~500HZ,2G10min/1cycle,period for 60 minutes,each axes |
||||||
safety |
Withstand voltage |
I/P-O/P:1.5KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC |
|||||
Isolated resistance |
I/P-O/P,I/P-FG,O/P-FG:100Mohms/500VDC |
||||||
Fit standard |
Safety standard |
Compliance toUL1012 |
|||||
EMC standard |
Compliance toEN55022,CLASSA |
||||||
others |
Dimension |
159*97*38mm(L*W*H) |
|||||
Weight/packing |
0.48kg/45pcs/22.5kg/0.041 m³/1.45CUFT |
||||||
note |
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and25℃of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. |
In a solar power generation system, the installation of a circuit breaker is a key step to ensure the safety of the system. The circuit breaker can not only prevent ...
The solar charge controller is one of the core components of the solar energy system. Its main function is to regulate the process of solar panels charging the batte...
In solar systems, car power supplies, and emergency power systems, the combination of 12V batteries and 1000W inverters is common. However, can a 12V battery with a ...
In a solar system, solar battery chargers and charge controllers are key components. Many users are curious whether these devices can be left connected all the time?...
GET A QUOTE